page_banner

products

China Wholesale Endotracheal Tube Cuffed Manufacturers - Closed Suction Catheter for single use – CHENKANG

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

We insist on the principle of development of 'High quality, Efficiency, Sincerity and Down-to-earth working approach' to deliver you with great provider of processing for Full Set Disposable Ppe, 20 Gsm Disposable Isolation Gown Pp, Isolation Gowns Disposable Non Woven, We hope to establish additional organization interactions with prospects all over the entire world.
China Wholesale Endotracheal Tube Cuffed Manufacturers - Closed Suction Catheter for single use – CHENKANG Detail:

Product Features

1. It can achieve continual oxygen supply without separation of artificial circuits.

2. The multiple-use plastic packing of suction catheter can avoid the infection caused by outside pathogens.

3. When sputum suction tube left artificial airway, the gas flow of respirator will not be influenced.

4. Closed suction catheter could both alleviate the complications and decrease oxygen partial pressure caused by suction, which effectively avoid cross infection.

The disadvantages of open suction catheter

In each sputum suction process, the artificial airway shall be separated from the ventilator, the mechanical ventilation shall be interrupted, and the sputum suction tube shall be exposed to the atmosphere for operation. Open suction may cause the following complications:

1. Arrhythmia interference and low blood oxygen;

2. Significantly reduce airway pressure, lung volume and blood oxygen saturation;

3. Airway pollution and environmental pollution;

4. Development of ventilator-associated pneumonia (VAP).

The advantages of Closed Suction Catheter

It can solve the following problems such as interruption of ventilator treatment, cross infection and environmental pollution:

1. It does not need to be separated from the artificial respiration circuit for sustainable oxygen supply.

2. The repeatedly used sputum suction tube is wrapped with a plastic sleeve to avoid contact with the outside world.

3. After sputum suction, the sputum suction tube leaves the artificial airway and will not interfere with the gas flow of the ventilator.

4. Closed sputum suction tube can significantly reduce the complications caused by sputum suction, avoid the decrease of oxygen partial pressure caused by repeated off-line sputum suction, and effectively avoid cross infection.

5. Improve the work efficiency of nurses. Compared with the open sputum suction, the closed type reduces the operations of opening the disposable sputum suction tube and disconnecting the ventilator, simplifies the sputum suction process, saves time and manpower compared with the open sputum suction, improves the work efficiency of nurses, and can respond to the needs of patients in time. After studying 149 closed suction and 127 open suction in 35 patients living in ICU after trauma, it is reported that the average time of closed suction in the whole process of each operation is 93s, while that of open suction is 153S.

CLosed Suction Catheter for Single Use


Product detail pictures:

China Wholesale Endotracheal Tube Cuffed Manufacturers - Closed Suction Catheter for single use – CHENKANG detail pictures

China Wholesale Endotracheal Tube Cuffed Manufacturers - Closed Suction Catheter for single use – CHENKANG detail pictures

China Wholesale Endotracheal Tube Cuffed Manufacturers - Closed Suction Catheter for single use – CHENKANG detail pictures

China Wholesale Endotracheal Tube Cuffed Manufacturers - Closed Suction Catheter for single use – CHENKANG detail pictures

China Wholesale Endotracheal Tube Cuffed Manufacturers - Closed Suction Catheter for single use – CHENKANG detail pictures

China Wholesale Endotracheal Tube Cuffed Manufacturers - Closed Suction Catheter for single use – CHENKANG detail pictures

China Wholesale Endotracheal Tube Cuffed Manufacturers - Closed Suction Catheter for single use – CHENKANG detail pictures

China Wholesale Endotracheal Tube Cuffed Manufacturers - Closed Suction Catheter for single use – CHENKANG detail pictures

China Wholesale Endotracheal Tube Cuffed Manufacturers - Closed Suction Catheter for single use – CHENKANG detail pictures

China Wholesale Endotracheal Tube Cuffed Manufacturers - Closed Suction Catheter for single use – CHENKANG detail pictures

China Wholesale Endotracheal Tube Cuffed Manufacturers - Closed Suction Catheter for single use – CHENKANG detail pictures


Related Product Guide:

We believe that prolonged expression partnership is really a result of top of the range, value added support, rich encounter and personal contact for China Wholesale Endotracheal Tube Cuffed Manufacturers - Closed Suction Catheter for single use – CHENKANG , The product will supply to all over the world, such as: Malaysia, Irish, Munich, Today, We are with great passion and sincerity to further fulfill our global customers' needs with good quality and design innovation. We fully welcome customers from all over the world to establish stable and mutually beneficial business relationships, to have a bright future together.
  • Speaking of this cooperation with the Chinese manufacturer, I just want to say"well dodne", we are very satisfied.
    5 Stars By Quintina from Japan - 2017.08.18 18:38
    As an international trading company, we have numerous partners, but about your company, I just want to say, you are really good, wide range, good quality, reasonable prices, warm and thoughtful service, advanced technology and equipment and workers have professional training, feedback and product update is timely, in short, this is a very pleasant cooperation, and we look forward to the next cooperation!
    5 Stars By Penelope from Germany - 2017.11.20 15:58
    Write your message here and send it to us